Medium-specific welded steel cylinders

40–926 L vertical and horizontal platforms

Liquid Chlorine Welded Steel Cylinders

Welded steel cylinders configured for liquid chlorine service, with pressure rating, filling ratio, valve, outlet, coating and handling arrangement confirmed as one complete system.

STANDARD BASISGB/T 5100CONFIGURATIONMedium-specific
Liquid Chlorine Welded Steel CylindersLiquid Chlorine cylinder configurations

Available size platforms

Select capacity and installation form.

CapacityOutside diameterHeight / length*Nominal wallApprox. weightInstallation
40 LØ300 mmApprox. 845 mm6 mmApprox. 40.1 kgVertical
100 LØ400 mmApprox. 1060 mm6 mmApprox. 72 kgVertical
400 LØ600 mmApprox. 1800 mm8 mmApprox. 250 kgHorizontal
800 LØ800 mmApprox. 2000 mm10 mmApprox. 445 kgHorizontal
926 LØ800 mmApprox. 2255 mm10 mmApprox. 512 kgHorizontal

* Height or length excludes the valve. Not every medium is available in every capacity. Final dimensions and construction follow the approved service drawing.

Service configuration

Confirm the complete cylinder and filling system.

Pressure, filling ratio, valve, outlet, withdrawal arrangement, surface protection, marking and documentation are selected together for the intended medium.

MediumFormulaWPTPFilling ratioValveOutletDesign life
Liquid ChlorineCl₂2 MPa3 MPa1.25 kg/LQF-10G3/4*12 years

* Outlet shown for the current production configuration. Existing 40L and 100L cylinder fleets may use a G1/2 connection; confirm the filling system and valve interface before ordering.

Order confirmation

Information required before production.

01Filling medium and purity02Water capacity and quantity03Working and test pressure04Valve and outlet connection05Vertical or horizontal installation06Standard, marking and packing
IMPORTANTSimilar dimensions do not make cylinders interchangeable between media.

The Liquid Chlorine configuration uses 2 MPa working pressure, 1.25 kg/L filling ratio and a QF-10 valve. Production follows the final approved medium-specific drawing and order specification.

Technical enquiry

Send the medium, capacity and destination.

We will verify compatibility, pressure, filling ratio, valve interface, installation and documentation before quotation.